TGL and TGLJ – diameter 5.8 mm, -40 °C to 105 °C

These resistance temperature sensors with a cable and thermocouple temperature sensors with a cable are designed to measure the temperature of gaseous and liquid substances. The maximum temperature range of use of the sensors is -40 to 105 °C. Used type of lead-in cable is a PVC type with insulation up to 80 °C with shielding up to 105 °C without shielding. The diameter of the case also enables the encasement of special temperature sensors – KTY, SMT 160, DS 18B20, TSic etc. In combination with the stainless steel thermowell JTG8, the sensor can be used for measuring the temperature in pipelines, as well as a pressure device as defined in Government Regulation no. 26/2003 coll., as amended. the sensors are designed for universal use, the method of use must be chosen for the temperature and chemical resistance of the case and supply cable.

Specification

Sensor type TGL TGLJ
Use general for JTG 8 thermowell
Measuring range -40 to 105 °C (can be limited by the type of cable)
Type of sensing element* all types (Pt 100, Pt 1000, Ni 1000, Ni 10000, Ni 2226=T1, NTC, PTC, KTY, TSiC, DALLAS, thermocouples K, J, T and so on)
Ingress protection IP 67 in accordance with EN 60529, as amended
Case material stainless steel DIN 1.4571; 1.4301
Diameter of case 5.8 mm
Length of case L 40 and 60 mm
Lead-in cable PVC shielded 2 x 0.34 mm2 or 4 x 0.25 mm2 (-40 to 80 °C)
PVC unshielded 2 x 0.35 mm2 or 4 x 0.35 mm2 (-40 to 105 °C)
Wire resistance 0.11 Ω for 1 m of cable for 2-wire connection
Time response t0,5 < 7 s (in flowing water at 0.4 m.s-1) t0,9 < 45 s (in flowing water at 0.4 m.s-1)

Dimensional Draft

Wiring Diagram

Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.

Also, you can reach us on +44 (0) 1865400514