TG 40, -50 °C to 350 °C (400 °C short-term)

These right-angle resistance temperature sensors with a bayonet and thermocouple temperature sensors with a bayonet, are designed to measure temperature of solid substances, however, they may be used also to measure temperature of liquid and gaseous substances.

Due to temperature sensor design, the cable is led out at right angle to measuring part of the sensor. To fasten the temperature sensor into a point to be measured, the bayonet head that is screwed onto a spring is used. Combination of the bayonet nut, the spring and the corresponding bayonet adapter can provide higher pressure of the right-angle temperature sensor with the bayonet into the measured point. Maximum temperature range of right-angle temperature sensor use is -50 to 350 °C (400 °C for a short period). The range for each design variant is reduced with a type of the temperature sensing element and the supply cable. The temperature sensors meet ingress protection from IP 50 to IP 67 according to the EN 60529 standard, as amended, depending on the lead-in cable variant.

The right-angle temperature sensors with a bayonet mount are intended for operation in chemically non-aggressive environment. 

Specification

Sensor type TG 40
Sensing element* all types (Pt 100, Pt 1000, Ni 1000, Ni 10000,Ni 2226=T1, NTC, PTC, KTY, TSiC, DALLAS, TC K, TC J, TC T and so on)
Case material stainless steel DIN 1.4301
Diameter of case 6 mm or 8 mm
Diameter if case in contact part 8 mm or 10 mm
Length of case L 60 to 200 mm
Material of rectangular part stainless steel
Case end straight, semisphere R6 or apex 120°
Lead-in cable variations / Temperature range
(can be limited by type of sensing element – determine in documentation)
PVC shielded / -30 to 80 °C
PVC unshielded / -40 to 105 °C
silicone shielded / -50 to 200 °C
teflon shielded / -50 to 250 °C
with fibreglass (with metal braiding) / 0 to 400 °C
Ingress protection from IP 50 to IP 67 in accordance with EN 60529, as amended - according to the type of cable
Material / Dimension of bayonet head ⌀ 6 mm:nickel-plated brass / L = 16 mm, inner ⌀12.8 mm
⌀ 8 mm: nickel-plated brass / L = 18 mm, inner ⌀ 15 mm
Material / Dimension of spring ⌀ 6 mm: stainless steel DIN 1.4301/ L = 200 mm, outer ⌀ 8 mm,⌀ of wire 1 mm
⌀ 8 mm: stainless steel DIN 1.4301 / L = 200 mm, outer ⌀ 10 mm, ⌀ of wire 1 mm
Insulation resistance (between case and sensor) 200 MΩ at 500 VDC, 25 ± 3°C
Maximum permissible static pull on the lead-in cable 1 kg

*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Dimensional Draft

Wiring Diagram