These resistance temperature sensors with a cable and thermocouple temperature sensors with a cable are designed to measure the temperature of gaseous and liquid substances. The maximum temperature range of use of the sensors is -50 to 200 °C. Used type of lead-in cable has silicone insulation and shielding. The sensors are primarily designed for measuring the temperature in pipelines. There structure enables quicker response to changes in temperature and can be used as a pressure device as defined in Government Regulation no. 26/2003 coll., as amended. The sensors are designed for universal use. The method of use must be chosen with regard to the temperature and chemical resistance of the case and lead-in cable.
TG 1 and TG 2 – diameter 6 mm, -50 °C to 200 °C
- Home
- Products
- Sensors and Probes
- Temperature Sensors
- Temperature Sensors with Cable
- Temperature Sensors with a Thread
- TG 1 and TG 2 – diameter 6 mm, -50 °C to 200 °C
Specification
Sensor type | TG 1 | TG 2 |
---|---|---|
Measuring range | -50 °C to 200 °C (can be limited the type of cable, determine in documentation) | |
Type of sensing element* | all types (Pt 100, Pt 1000, Ni 1000, Ni 10000,Ni 2226=T1, NTC, PTC, KTY, TSiC, DALLAS, thermocouple K, thermocouple J, thermocouple T and so on) | |
Ingress protection | IP 67 in accordance with EN 60529, as amended | |
Thread / OK | M 10 x 1.5 / OK 12 | |
Material of the case | brass | stainless steel DIN1.4301 |
Diameter of case | 6 mm | |
Length of case L | 10 to 60 mm (in 10 mm) | 10 to 100 mm (in 10 mm) |
Lenght of thread L1 | 8 mm | 10 mm |
Lead-in cable |
shielded silicone 2 x 0.22 mm2 shielded silicone 4 x 0.15 mm2 |
|
Wire resistance | 0.16 Ω for 1 m of cable for 2-wire connection | |
Time response |
τ0.5 < 7 s (in flowing water at 0.4 m.s-1) |
τ0.9 < 9 s (in flowing water at 0.4 m.s-1) |
*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types. Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.
Dimensional Draft
Wiring Diagram
Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.
Also, you can reach us on +44 (0) 1865400514
Also, you can reach us on +44 (0) 1865400514