K160 Fast Response with a Metal Connection Head

These resistance-type sensors are intended for contact temperature measurements of liquid or gaseous substances. The structure of the sensor’s stem enables the sensor to be used for direct measuring of the temperature in ducts and ensures quick response of the sensor to changes in temperature. The standard operating temperature range is -30 to 130 °C. The sensors can be utilised for any control systems that are compatible with sensing element output signals or output signals quoted in the table of sensing element types.

The sensors are designed to be operated in a chemically non-aggressive environment

Specification

Sensor type Type of sensing element Maximum measuring DC current Measuring range
NK 160 Ni 1000/5000 1 mA -30 to 130 °C (connection head ambient temperature -30 to 100 °C)
NK 161 Ni 1000/6180 1 mA
NK 162 Ni 891 1 mA
PTK 160 Pt 100/3850 3 mA -50 to 130 °C (connection head ambient temperature -30 to 100 °C)
PTK 260 Pt 500/3850 1,5 mA
PTK 360 Pt 1000/3850 1 mA
HS 160 thermistor NTC 20 kΩ -30 to 130 °C 10 mW *)

*) maximum power consumption
Note: x = version A or version B

Sensor type NK 560 Note
Type of sensing element Pt 1000/3850
Output signal 4 to 20 mA
Measuring ranges -50 to 50 °C
-30 to 60 °C
0 to 35 °C
0 to 100 °C
0 to 150 °C
ambient temperature around the connection head -30 to 70 °C
Power supply (U) 11 to 30 VDC recommended value 24 VDC
Load resistance 150 Ω for power supply 12 VDC
700 Ω for power supply 24 VDC
Output signal - sensing elements break > 24 mA
Output signal - sensing element short circuit < 3.5 mA

*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

Others Parametrs
Accuracy class Ni sensing elements: B class, Δt = ± (0.4 + 0.007t), for t ≥ 0; Δt = ± (0.4 + 0.028|t|), for t ≤ 0 in °C;
Pt sensing elements: B class according EN 60751, Δt = ± (0.3 + 0.005|t|) in °C NTC 20 kΩ: ± 1 °C for the range 0 to 70 °C
Measuring error for NK 560 < 0.6 % of the measuring range, minimum 0.5 °C
Sensor connection according to the wiring diagram
Standard length of stem L1 50, 100, 160, 220 mm
Diameter of the stem 4 ± 0.1 mm
Standard thread G 1/2"
Nominal pressure of the stem PN 25
Time response τ0,5 < 4 s (in flowing water at 0.4 m.s-1)
Recommended wire cross section 0.35 to 1.5 mm2
Insulation resistance > 200 MΩ at 500 VDC, 25° ± 3 °C; humidity < 85 %
Ingress protection IP 54 in accordance with EN 60529
Material of the sensor stem stainless steel DIN 1.4301
Material of connection head aluminium alloy, LIMATHERM MA
Operating conditions
ambient temperature:
-30 °C to 100 °C; -30 °C to 70 °C with a converter
relative humidity:
max. 100 % (at the ambient temperature 25 °C)
atmospheric pressure:
70 to 107 kPa
Weight approximately 0.2 kg

*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.

MAXIMUM FLOW VELOCITY OF THE MEASURED MEDIUM - AIR AND WATER VAPOUR / WATER [m.s-1]
Length of the stem up to 60 mm > 60 to 100 mm > 100 to 160 mm > 160 to 220 mm
Values for diameter of the stem 4 mm 8 / 0.8 6 / 0.6 3.2 / 0.4 1.0 / 0.25

Dimensional Draft

Wiring Diagram

Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.

Also, you can reach us on +44 (0) 1865400514