The temperature sensors are designed to be operated in a chemically non-aggressive environment.
K120 with a Stem and Metal Connection Head
- Home
- Products
- Sensors and Probes
- Temperature Sensors
- Temperature Sensors with a Connection Head up to 600 °C
- Temperature Sensors up to 250°C
- K120 with a Stem and Metal Connection Head
These resistance-type temperature sensors are intended for contact temperature measurements of liquid or gaseous substances. The temperature sensor-central holder combination is suitable for temperature measurements in air condition ducts. The temperature sensor-thermowell combination is suitable for temperature measurements in tubing. The sensor variant with welded thread is ideal for direct measuring of mediums in ducts. The standard operating temperature range is -30 to 200 °C. By using a sensor with a longer stem the upper limit of allowable temperature can be extended up to 250 °C. The temperature sensors can be utilised for any control systems that are compatible with sensing element output signals or output signals quoted in the table of sensing element types.
The temperature sensors are designed to be operated in a chemically non-aggressive environment.
The temperature sensors are designed to be operated in a chemically non-aggressive environment.
Specification
Sensor type | Type of sensing element | Maximum measuring DC current | Measuring range |
---|---|---|---|
NK 120 | Ni 1000/5000 | 1 mA | -30 to 200 °C (connection head ambient temperature -30 to 100°C) |
NK 121 | Ni 1000/6180 | 1 mA | -30 to 200 °C (connection head ambient temperature -30 to 100°C) |
NK 122 | Ni 891 | 1 mA | -30 to 200 °C (connection head ambient temperature -30 to 100°C) |
NK 320 | Ni 10000/5000 | 0.3 mA | -30 to 200 °C (connection head ambient temperature -30 to 100°C) |
NK 321 | Ni 10000/6180 | 0.3 mA | -30 to 200 °C (connection head ambient temperature -30 to 100°C) |
NK 123 | T1 = Ni 2226 | 0.7 mA | -30 to 150 °C |
PTK 120 | Pt 100/3850 | 3 mA | - 50 to 200 °c (connection head ambient temperature -30 to 100 °C) |
PTK 220 | Pt 500/3850 | 1.5 mA | |
PTK 320 | Pt 1000/3850 | 1 mA | |
HK 120 | thermistor NTC 20 kΩ | 10 mW *) | -30 to 150 °C |
*) maximum power consumption
Note: x = version A or version B
Sensor type | NK 520 | Note |
---|---|---|
Type of sensing element | Pt 1000/3850 | |
Output signal | 4 to 20 mA | |
Measuring ranges |
-50 to 50 °C -30 to 60 °C 0 to 35 °C 0 to 100 °C 0 to 150 °C 0 to 200 °C 0 to 250 °C |
ambient temperature around the connection head -30 to 70 °C |
Error of the measurement | < 0.6 % of the range | no less than 0.5 °C |
Power supply (U) | 11 to 30 VDC | recommended value 24 VDC |
Load resistance |
150 Ω for power supply 12 VDC 700 Ω for power supply 24 VDC |
|
Output signal - sensing elements break | > 24 mA | |
Output signal - sensing element short circuit | < 3.5 mA |
*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.
Others Parametrs | |
---|---|
Accuracy class |
Ni sensing elements: B class, Δt = ± (0.4 + 0.007t), for t ≥ 0; Δt = ± (0.4 + 0.028|t|), for t ≤ 0 in °C; Pt sensing elements: B class according EN 60751, Δt = ± (0.3 + 0.005|t|) in °C NTC 20 kΩ: ± 1 °C for the range 0 to 70 °C |
Sensor connection | according to the wiring diagram |
Standard length of stem L1 | 70, 120, 180, 240, 300, 360, 420 mm |
Time response | τ0,5 < 9 s (in flowing water at 0.4 m.s-1) |
Recommended wire cross section - sensors with the grommet | 0.35 to 1.5 mm2 |
Insulation resistance | > 200 MΩ at 500 VDC, 25° ± 3 °C; humidity < 85 % |
Ingress protection | IP 54 in accordance with EN 60529 |
Material of the stem | stainless steel DIN 1.4301 |
Type of connection head | LIMATHERM MA |
Material of connection head | aluminium alloy |
Operating conditions |
|
Weight | approximately 0.15 kg |
*) Certain technical specifications of thermocouple sensors (lead wires, IP rating, etc.) may differ with different types.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.
Dimensional Draft
Wiring Diagram
Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.
Also, you can reach us on +44 (0) 1865400514
Also, you can reach us on +44 (0) 1865400514