IoT WIRELESS DATA LOGGER FOR 3 CURRENT INPUTS 0-20mA AND TWO-STATE INPUT, WITH BUILT-IN 4G MODEM

GSM datalogger is designed to record 3 current inputs and 1 binary input. In case of exceeded set limits, SMS and JSON messages can be sent via 4G data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.

It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.

GSM recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

CODE: U6841G

INCLUDED IN DELIVERY

• U6841G
• Instruction Manual
• Traceable Calibration Certificate
• Rechargeable Battery
• Power Supply
• USB-C Cable
• FREE Analytical Software COMET Vision
• COMET Cloud for 3 Months

TECHNICAL DATA

Measured Value
Current
Two-state signal

GSM Modem Parameters
LTE Cat 1: LTE FDD/GSM/GPRS/EDGE
Supported network types:
GSM/GPRS/EDGE 900/1800 MHz
LTE FDD B1/B3/B5/B7/B8/B20

Current Input
Measuring range: 0-20mA DC
Resolution: better than 1µA
Accuracy: ± 20 µA
Input resistance: approx. 100 Ω
Minimum Current: 0mA (open circuit)
Maximum Current: limited to approx. 40mA

Binary Input
Parameters of the voltage contact „L” Level input voltage: < 0,8 V(*);
„H“ level input voltage: > 2 V;
Minimum voltage applicable: 0V;
Maximum voltage applicable: +30V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state: < 10 kOhm;
Contact resistance in the „switched-off“ state: > 2 MOhm;
Contact voltage in the „switched-off“ state: ca 3V;
Minimum state duration necessary for latching the state:1s

General Technical Data
Operating temperature: -20 to +60 °C
Channels: 3x current input, 1x binary input
Memory:
500,000 values in noncyclic logging mode.
350,000 values in cyclic record mode
Recording interval to the internal memory:
adjustable from 1 second to 24 hours
Recording interval to the COMET Cloud:
from 5 minutes
Interval for measuring and evaluating alarms:
adjustable 1 s, 10 s, 1 min.
Recording mode:
• noncyclic - data logging stops after filling the memory.
• cyclic - after filling memory oldest data is overwritten by new.
Real time clock: year, leap year, month, day, hour, minute, second
Power:
rechargeable Li-Ion battery A8200, 3.6V/5200mAh
Protection class: IP20
Dimensions: 61 x 93 x 53 mm, with antenna 120 x 93 x 53 mm
Weight (including batteries): approx. 270 g.
Warranty: 3 years
Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.

Also, you can reach us on +44 (0) 1865400514