C-Pro 3 NODE kilo

c-pro 3 NODE kilo is a range of programmable controllers with many communications protocols and I/Os (up to 40) suitable to a vast range of applications (mainly HVAC/R).

The application software can be designed in an intuitive way thanks to the UNI-PRO 3 integrated development environment.

The Ethernet port with built-in web server provides browser access to the HTML (5) pages of the application developed and the simultaneous presence of two RS-485 makes possible the joint use of such communications protocols as MODBUS TCP, MQTT, BACnet, etc. These features facilitate communications between devices and their use in control and maintenance systems, both onsite and remote.
The data-logging function enables recording of up to 32 process variables/32 events to facilitate unit monitoring (e.g., energy consumption) and data traceability (which can be downloaded in CSV format by USB). The USB and Ethernet ports make it possible to reprogram, download and debug application software onsite or remotely, thus simplifying commissioning and subsequent diagnostics.

c-pro 3 NODE kilo is available in standard 8 DIN module format, blind or with a built-in 6-key user interface, with an LCD graphic display or a LED display with function icons.

Technical Features

Programmable controllers c-pro 3 NODE kilo c-pro 3 NODE kilo+
EPK4BHX EPK4BHR EPK4LHX EPK4LHR EPK4DHX EPK4DHR EPK4BHQ EPK4BHT EPK4LHQ EPK4LHT EPK4DHQ EPK4DHT
Version
blind
built-in LED (4+4 digits custom display)
built-in LCD (128 x 64 pixel single colour LCD graphic display)
Dimensions
DIN modules 8 8 8 8 8 8 8 8 8 8 8 8
Connections
removable screw terminal blocks
Power supply
24 VAC/DC not isolated
Analog inputs
PTC/NTC/Pt 1000 3 3 3 3 3 3 4 4 4 4 4 4
PTC/NTC/Pt 1000/0-20 mA/4-20 mA/0-5 V ratiometric/0-10 V 3 3 3 3 3 3 6 6 6 6 6 6
Digital inputs (for NA/NC contact)
optoisolated 24 VAC/DC 50/60 Hz contacts 3 3 3 3 3 3 11 11 11 11 11 11
optoisolated 24 VAC/DC 2 KHz contacts 2 2 2 2 2 2 2 2 2 2 2 2
Analog outputs
0-10 V 2 2 2 2 2 2
PWM/0-10 V 2 2 2 2 2 2 2 2 2 2 2 2
0-20 mA/4-20 mA/0-10 V 1 1 1 1 1 1 2 2 2 2 2 2
Digital outputs (electromechanical relays; res. A @ 250 VAC)
3 A SPST 6 4 6 4 6 4 9 5 9 5 9 5
3 A SPDT 1 1 1 1 1 1 2 2 2 2 2 2
Digital outputs (command for solid state relay)
24 VAC/DC, 0.6 A max 2 2 2 4 4 4
Communication ports
MODBUS slave RS-485 1 1 1 1 1 1 1 1 1 1 1 1
RS-485 (MODBUS master/slave, BACnet MS/TP) (1) 1 1 1 1 1 1 1 1 1 1 1 1
CANBUS CAN 1 1 1 1 1 1 1 1 1 1 1 1
USB 1 1 1 1 1 1 1 1 1 1 1 1
Ethernet (MODBUS TCP, Web Server, BACnet IP) (1) 1 1 1 1 1 1 1 1 1 1 1 1
Other features
real time clock

Notes

(1) The BACnet communications protocol can be used only in alternative to the Web Server function.