Temperature Sensors with Magnetic Fixing

The temperature sensors are intended for contact temperature measurements of ferromagnetic materials. The contact with measuring surface is provided by springing of the measuring surface. The plastic connection head is provided with a cable outlet ending (the terminal board is placed in the connection head) or a connector. The standard operating temperature range is -30 to 100 °C. The sensors can be utilised for any control systems that are compatible with sensing element output signals or output signals quoted in the table of sensing element types.

The sensors are designed to be operated in a chemically non-aggressive environment.

Specification

Sensor type
(K - with connector)
Type of sensing element Maximum measuring DC current Measuring range
NS 190
NS 190K
Ni 1000/5000 1 mA -30 to 100°C
NS 191
NS 191K
Ni 1000/6180 1 mA
NS 192
NS 192K
Ni 891 1 mA
NS 390
NS 390K
Ni 10000/5000 0,3 mA
NS 391
NS 391K
Ni 10000/6180 0,3 mA
NS 193
NS 193K
T1 = Ni 2226 0,7 mA -30 to 100 °C
PTS 190
PTS 190K
Pt 100/3850 3 mA
PTS 290
PTS 290K
Pt 500/3850 1,5 mA
PTS 390
PTS 390K
Pt 1000/3850 1 mA
HS 190
HS 190K
thermistor NTC 20 kΩ 1 mW *)

*) maximum power consumption
Note: x = version A or version B

Sensor type
(K - with connector)
NS 590
NS 590K
NS 790
NS 790K
Note
Type of sensing element Pt 1000/3850 Pt 1000/3850
Output signal 4 to 20 mA 0 to 10 V
Measuring ranges -30 to 60 °C
0 to 35 °C
0 to 100 °C
0 to 150 °C
-30 to 60 °C
0 to 35 °C
0 to 100 °C
0 to 150 °C
ambient temperature around the connection head -30 to 70 °C
Power supply (U) 11.5 to 30 VDC 15 to 30 VDC Recommended value 24 VDC
Load resistance 150 Ω for power supply 12 VDC
700 Ω for power supply 24 VDC
> 10 kΩ
Output signal - sensing elements break > 24 mA > 10.5 V
Output signal - sensing element short < 3.5 mA ~ 0 V

**)According to the customer‘s requirement, it is possible to provide a customized measuring range from -40 to 150 °C; the minimum span of the range must be 35 °C (e.g. -20 to 15 °C; -30 to 80 °C)

Others Parametrs
Accuracy class Ni sensing elements: B class, Δt = ± (0.4 + 0.007t), for t ≥ 0; Δt = ± (0.4 + 0.028|t|), for t ≤ 0 in °C;
Pt sensing elements: B class according EN 60751, Δt = ± (0.3 + 0.005|t|) in °C
NTC 20 kΩ: ± 1 °C for the range 0 to 70 °C
Measuring error NS 590(K) and NS 790(K) < 0.6 % of the measuring range, minimum 0.5 °C
Sensor connection according to the wiring diagram
Measuring surface diameter 19 mm
Measuring surface pressure 5 N
Adhesive power of the sensor 60 N
Recommended wire cross section - sensors with the grommet 0.35 to 1.5 mm2
Type of connector in the head - sensors with connector RSFM4 - Lumberg
Insulation resistance > 200 MΩ at 500 VDC, 25° ± 3 °C; humidity < 85 %
Ingress protection IP 52 in accordance with EN 60529
Material of the head LEXAN 500R
Operating conditions
ambient temperature:
-30 to 100 °C; -30 to 70 °C with a converter
relative humidity:
max. 100 % (at the ambient temperature 25 °C)
atmospheric pressure:
70 to 107 kPa
Weight approximately 0.1 kg (NS 590, NS 790); 0.08kg (passive)

*) The temperature sensor´s measurement error is dependent on the influence of ambient temperature, environmental variables and the characteristics of the measured surface (error of method).
**) It is recommended to apply heat-conducting paste or silicon grease to the measured surface, which will ensure faster response time and minimise the measurement error of the contact temperature sensor.
Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your deale

Dimensional Draft

Wiring Diagram

Visit our downloads page to view technical characteristics or contact our technical sales department for more information, prices or with your specifications.

Also, you can reach us on +44 (0) 1865400514